CHFKF - 25 YEAR SILICONIZED ACRYLIC CLEAR, 0877

  • MSDS: CHFKF
  • Manufacturer: RED DEVIL INC
  • Product Name: 25 YEAR SILICONIZED ACRYLIC CLEAR, 0877
  • National Stock Number: 8030-00N086406
Product Identification

Product ID:25 YEAR SILICONIZED ACRYLIC CLEAR, 0877
MSDS Date:07/27/1990
FSC:8030
NIIN:00N086406
MSDS Number: CHFKF

Responsible Party
RED DEVIL INC
ONE WEBB ST
PRYOR, OK 74361
US

Emergency Phone: 918-825-5744

Info Phone: 918-825-5744

Cage: 23577

Contractor
RED DEVIL, INCORPORATED
A PRYOR, OK 74361 US

Telephone: 918-825-5744

Cage: 23577

Ingredients

SOLVENT NAPHTHA, PETROLEUM, MEDIUM ALIPHATIC; (MINERAL

CAS: 64742-88-7

OSHA PEL N/K

ACGIH TLV: N/K


ETHANOL, 2-ETHOXY-; (OCTYLPHENOXYPOLY (ETHOXYETHANOL))

CAS: 110-80-5

RTECS: KK8050000

OSHA PEL 200 PPM, S

ACGIH TLV: 5 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ETHYLENE GLYCOL (SARA 313) (CERCLA)

CAS: 107-21-1

RTECS: KW2975000

OSHA PEL N/K

ACGIH TLV: 50 PPM, VAPOR, C

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF DUST GENERATED FROM
DRIED PRODUCT MAY CAUSE RESPIRATORY IRRITATION. HIGH VAPOR
CONCENTRATIONS MAY PRODUCE HEADACHE, DIZZINESS AND NAUSEA.
PROLONGED OR REPEATED SKIN CONTACT MAY LEAD TO D RYING AND
IRRITATION. EYE CONTACT MAY CAUSE BURNING AND IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: IMMED FLUSH EYES W/LARGE AMOUNTS OF WATER FOR AT LEAST
15 MINUTES WHILE HOLDING EYE OPEN. GET MED ATTN IF IRRITATION
PERSISTS. SKIN: WIPE MATL FROM SKIN W/CLOTH OR PAPER TOWEL, THEN
WASH EXPOSED SKIN W/SOAP & WATER. GET MEDICAL HELP IF IRRITATION
PERSISTS. INHAL: MOVE VICTIM TO FRESH AIR & TREAT W/ARTIFICIAL
RESPIRATION IF NEEDED. INGEST: CONTACT LOCAL POISON CONTROL CENTER
OR MD IMMED!

Fire Fighting

Flash Point:<140F,<60C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL OR FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . USE WATER SPRAY OR FOG TO COOL FIRE-EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:CLEAN UP WITH ABSORBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A CLOSED CONTAINER IN DRY
AREA.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NOT NORMALLY REQUIRED. IF TLV IS EXCEEDED OR FOR
SYMPTOMS OF OVEREXPOSURE, A NIOSH APPROVED RESPIRATOR FOR ORGANIC
VAPORS.
Ventilation:PROVIDE ADEQUATE GENERAL DILUTION VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Vapor Density:>1
Spec Gravity:>1.0 (H*2O=1)
pH:9.0
Evaporation Rate & Reference:<1
Solubility in Water:MODERATE
Appearance and Odor:WHITE PASTE; MILD ACRYLIC/AMMONIA ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXTREME HEAT, OPEN FLAME.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
ACRYLIC ACID.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.